CX3R-D Amplifier
The CX3R-D is a compact amplifier with a 1.2 GHz frequency range in the downstream and up to 204 MHz in the upstream. The high-performance output stage uses the latest technology to improve RF performance over the entire frequency range and ensures low power consumption. Adjustments use electronic controls, eliminating the need for plug-in attenuators or equalizers. It is small in size and light in weight but delivers performance and functionality on a scale that makes it ideal for any distribution challenges at a competitive price.
Features at a glance:
- GaN amplifier technology
- Diplexers for 65/85/204 MHz upstream
- Bypass port at the input
- Remote powered
- Optional: remote ingress switching
- Optional: power save
Distribution Amplifier
Power Insert
Block Diagram
Dedicated Port
RIS and PowerSave
Product Specifications
Downstream signal path
Frequency range
85…1218 MHz
Return loss
18.5 dB @ 80 MHz -1.5 dB/oct.
Gain
44 dB
Input attenuator control range
0…20 dB
Input equalizer control range
0…25 dB
Cable simulator
0 / -13 dB
Flatness
± 0.75 dB
Mid-stage gain
0…12 dB
Mid-stage slope
0…14 dB
Noise figure at 1218 MHz, flat, high gain
8.5 dB
Test point
20 dB
Umax (138 QAM channels, 13 dB sloped)
109 dBµV
Upstream signal path
Frequency range
5…204 MHz
Return loss
20 dB @ 40 MHz -1.5 dB/oct.
18.5 dB @ 80 MHz -1.5 dB/oct.
18.5 dB @ 80 MHz -1.5 dB/oct.
Gain
28 dB
Gain control range (interstage)
0…15 dB
Gain control range (output)
0…15 dB
Slope control range
0…16 dB
Noise figure at high gain
9.5 dB
Test point
20 dB
General
Supply Voltage
28…90 VAC/50 Hz
Power Consumption
18 W
Max. current input to Bypass
2 A
Hum
70 dB
Operating temperature
– 20 ° to + 65 °C
Class of enclosure
IP 67
Dimensions (h x w x h)
220 x 210 x 80 mm
Test Point connector
F-female
EMC compatibility
EN 60728-2
Safety
EN 60728-11
Surge
2 kV, IEC 60728-3
ESD
2 kV